The BF100 Disposable Breathing System Filter is used to be installed at the air inlet of the breathing gas supply device. The BF100 Disposable Breathing System Filter can filter particles larger than 0.3 μm in the gas entering the breathing gas Supply device. The BF100 Disposable Breathing System Filter is intended for adults and children (age ≥ 1 month & weight ≥ 3 kg).
The CS02 Reusable Water Chamber in conjunction with the breathing gas supply
device heating and humidifying the dry and cold gas provides the suitable breathing
gas for the patients. The product is intended for adults and children (age ≥ 1 month &
weight ≥ 3 kg).
The product is for patients by prescription in the home or medical institutional
environment
The HFNC oxygen therapy is carried out using air oxygen blender ,active humidifier single heated tube and nasal cannula it is respiratory support. The HFNC continuous to increase easily set up it may also create positive pharyngeal pressure to reduce work of breathing the device midway classical oxygen delivery system like high concentrations CPAP generators . It is designed a heated humifided mixture of air and oxygen at a high flow than the inspiratory flow. It adjust the flow rate and body weight provides a degree of distending pressure. It also decrease works of breathing and oxygenation . It utilizes a soft large bore nasal prongs it is similar to used on mechanical ventilator with the HFNC. It overcome the leading causes of discomfort seen with conventional oxygen therapy. It is a difficult quality level of PEEP generated by the high flow. It support breathing in people with acute heart failure , Acute respiratory distress syndrome. It avoids rebreathing of co2 gas and therefore decreased anatomize dead space. It promoted a slow and deep breathing . it airway hydrated and it improved mucus clearance . This improves FRC and reduce work of breathing it flows used are high humidification is necessary to avoid drying of respiratory secretions and for maintaining nasal cilia function . It is mild positive airway pressure and lung volume recruitment. It will titrate FIO2 and flow to promote comfort and oxygen saturation. It ensure the monitor spo2 saturation and pleth wave form. It ensure maintain a o2 saturation on NRB mask It delivery of optimally humidified and warm gases It decreased body energy expenditure. It is used for intubation and extubation support as well as treatment and prevention of post operative respiratory failure and for oxygenation patients during trails or bronchoscopy.
Device Size |
Dimensions: 335 mm × 227 mm × 158 mm Weight: about 4 kg Water capacity: To maximum fill line 235 mL |
Product Use, Transport and Storage |
Operation Temperature: 18°C to 28°C (64.4˚F to 82.4˚F) Humidity: ≤ 93%, Non-condensing Atmospheric Pressure: 760 hPa to 1060 hPa Transport and Storage -25°C to +70°C (-13˚F to +158˚F ≤ 93%, Non-condensing 760 hPa to 1060 hPa |
Heated humidification |
Humidifier Output: No less than 33 mg/L, at 37 °C target Maximum Delivered Gas Temperature: ≤ 43°C |
Mode of Operation |
Continuous |
Work Mode |
HFlow, LFlow, AutoFlow, SmartFlow |
SD Card |
SD card can record data and fault information |
AC Power Consumption |
220 V - 240 V ~, 50 Hz / 60 Hz, 2.5 A |
Type of Protection against Electric Shock |
Class II Equipment |
Sound Power Level |
< 28 dB (A), When the working mode of the device is HFlow, and the output flow is 25 L/min |
Maximum oxygen input flow |
80 L/min |
FiO2 |
Range: 21% ~ 100 %, binning interval 1% Margin of Error: ± (5% + 5% set value) |
FiO2 Display Accuracy |
± (5% + 5% set value) |
Temp |
Range: 25°C ~ 45°C |
Temp Display Accuracy |
± 2°C |
Flow |
Range: 2 L/min ~ 80 L/min Margin of Error: ± (2 L + 10% set value) |
Flow Display Accuracy |
± (2 L + 10% set value) |
sPEEP |
Range: 0 ~ 20 hPa Margin of Error: ± (1 hPa + 20% set value) |
Humidity Compensation |
Range: -3~3,-3、-2、-1、0、1、2、3, the higher the range, the higher the humidification output |
Flow Step Interval |
Range: 15 L/min ~ 80 L/min |
Tube |
Length: 1.8 m Margin of Error: ± 10% The connection should not fall off under the 45 N tension. |
Specification of Patient Connector |
φ 18 mm cone joint |
Heater Plate AC Power Consumption |
220 V - 240 V ~, 50 Hz / 60 Hz, 1 A |