pa
|
• Vivo 2 is intended for spontaneously breathing patients.
• The Vivo 2 is a new generation ventilator designed for personalized and comfortable non-invasive respiratory support for non-dependent patients with chronic breathing insufficiency.
• The intuitive interface ensures ease of use. A comprehensive set of modes and extensive monitoring capabilities allow for great flexibility, making the ventilator a perfect choice for a variety of patients.
• Vivo 2 is intended to provide non-invasive ventilation for patients weighing over 10 kg who require long-term support or mechanical ventilation for respiratory impairment, with or without obstructive sleep apnea.
• A BIPAP is a Non invasive therapy it a pressure controlled in a spontaneous breathing. • It is used to help you breathe easier when you have condition that make breathing difficult . • Obstructive sleep apnea is a serious condition in which your breathing stop and starts repeatedly while you are asleep. • Chronic obstructive pulmonary disease (copd) • Asthma • Obesity hypoventilation syndrome. • Heart condition such as congestive heart failure or coronary artery disease • A neurological or neuromuscular disorder that affect your ability to breathe. • Poor breathing after a medical procedure such as surgery. • The machine works by pushing the pressurized air into your lungs. • It reduces burden on respiratory muscles and lungs to inhale and exhale • The machine motor blows air through the tube certain amount of required pressure. • The pressurized air enters your body through the mask or plugs. • It eliminates need for using a ventilator that makes uses of a tube that goes down into your throat without used for tracheotomy. • A tracheotomy is a procedure to create a hole in your neck to let you breathe through the trachea.
Ventilation modes |
PSV, PCV, CPAP, S, S/T, T, Tgv |
Inspiratory Pressure |
4-30 cm H2O |
EPAP |
2-20 cm H2O |
CPAP |
4-20 cm H2O |
Breath Rate |
0-40 bpm |
Inspiratory Time |
0.3-3 s |
Rise Time |
1-9 |
Inspiratory Trigger |
1-9 |
Expiratory Trigger |
1-9 |
Minimum Inspiratory Time |
Off, 0.3-3s |
Maximum Inspiratory Time |
Off, 0.3-3s |
Target Volume |
100-1500ml |
Ramp Up |
Off, 10-60 min |
Ramp Down |
Off, 10-60 min |
Ramp Pressure |
2-20 cm H2O |
Humidifier |
Off, Level 1-5 |
Heated Wire |
Off, Level 1-5 |
Displayed data |
Ppeak, EPAP, Leakage, MVe, Vte, %in TgV, Total Rate, I:E, Spont Rate, %Spont, |
Mains supply |
100 to 240 V AC |
External DC |
24 V DC |
Fixed Alarms |
High-Pressure Limitation, Power Failure, SpO2 Disconnected, SpO2 Artifact, Ambient |
Adjustable Alarms |
High-Pressure, Low Pressure, High Breath Rate, Low Breath Rate, High MV, Low MV, |
W x H x D |
166 x 185 x 200 mm |
Weight |
1.6 kg |
Noise level (at 10 cm H2O constant pressure) |
30dB(A) |