• Vivo 3 is intended for spontaneously breathing patients.
• The Vivo 3 is a new generation bi-level ventilator designed for personalized and comfortable respiratory support – both non-invasive and invasive – for non-dependent patients with chronic breathing insufficiency.
• The intuitive interface ensures ease of use. A comprehensive set of modes and extensive monitoring capabilities allow for great flexibility, making the ventilator a perfect choice for a variety of patients.
• Vivo 3 is intended to provide non-invasive or invasive ventilation for patients weighing over 10 kg who require longterm support or mechanical ventilation for respiratory insufficiency or respiratory failure, with or without obstructive sleep apnea.
• A BIPAP is a Non invasive therapy it a pressure controlled in a spontaneous breathing. • It is used to help you breathe easier when you have condition that make breathing difficult . • Obstructive sleep apnea is a serious condition in which your breathing stop and starts repeatedly while you are asleep. • Chronic obstructive pulmonary disease (copd) • Asthma • Obesity hypoventilation syndrome. • Heart condition such as congestive heart failure or coronary artery disease • A neurological or neuromuscular disorder that affect your ability to breathe. • Poor breathing after a medical procedure such as surgery. • The machine works by pushing the pressurized air into your lungs. • It reduces burden on respiratory muscles and lungs to inhale and exhale • The machine motor blows air through the tube certain amount of required pressure. • The pressurized air enters your body through the mask or plugs. • It eliminates need for using a ventilator that makes uses of a tube that goes down into your throat without used for tracheotomy. • A tracheotomy is a procedure to create a hole in your neck to let you breathe through the trachea.
Ventilation Modes |
S, ST, T, PSV, PCV+A , CPAP |
Adult/Peadiatric |
>10kg |
Profiles |
3 settable profiles |
IPAP
|
4 – 40 cmH2O |
EPAP |
2 – 20 cm H2O |
Breath Rate/Back-up Rate |
0-40 bpm |
Inspiratory Time |
0.3 – 3s |
Rise Time |
1 – 9 |
Inspiratory Trigger |
1 – 9 |
Expiratory Trigger |
1 – 9 |
Minimum Inspiratory Time |
Off, 0.3 – 3 s |
Maximum Inspiratory Time |
Off, 0.3 – 3 s |
Target Volume |
100 – 1500 ml |
Auto-EPAP |
On/Off, Pressure Limit: Max EPAP +2 cmH2O – 40 cmH2O, PS 2-38cm Min/Max EPAP: 2 – 20 cmH2O, EPAP Step: 0.5 – 2 cmH2O, Relax Time: 2-12 mins/Off |
HFNT |
4-60L/min |
Ramp (Up/Down) |
Off 10-60mins |
Humidifier Level |
1-5 |
Heated Circuit |
Off, 1-5 |
Patient Circuit |
15mm, 22mm, Custom |
O2 Bleed in (Device) |
0-30L/min |
Displayed data |
Ppeak, EPAP, Leakage, MV, Vte % in TgV, Total Rate I:E, Spont Rate, % spont, Inspiratory time, Rise time, SpO2, Pulse, Rate |
Power Supplies
|
Mains supply External DC Internal battery
|
Alarms |
High Pressure, Low Pressure, High Breath Rate, Low Breath Rate High MV, Low MV, Rebreathing Apnea, Disconnection, High SpO2, Low SpO2, High Pulse Rate, Low Pulse Rate, Low Last Power Source |
Dimensions
|
W x H x D |
Weight |
1.8 kg |
Noise level (at 10 cmH2O constant pressure) |
Less than 28 dB(A) |
Connectivity and Software |
Built-in connectivity Compatible Software Plug-and-Play accessories
|
Humidification |
Integrable water chamber |
Circuits |
Cleanable & Disposable leakage circuits with/without heated wires |
Compliance Data (on Screen) |
Min Daily Usage Off, 1-24hrs, Total Usage Hours, Total Days, Days with Usage Average Usage, Days Compliant, AHI |