• Suitable for Cardiothoracic Patients
• Rugged and Strong design for rough use
• Most Compact pump (2.2 L)
• Lightest pump (1.75 kg)
• Long battery backup (up to 10 Hrs )
• Dosage ramp up and tapper down function
• Custom programmable mode to accept any brand of syringe
• Auto / Purge bolus facility
• Multiple safety alarm facility
• Inline program during infusion
• A syringe is a small infusion pump used to deliver small amount of fluids or medications to a patient. • Syringe pumps are more compact and less weight than infusion pumps, it could adjust particular volume of syringes only. • It works on the principle of Pascal’s principle. When a pressure is applied in closed container is the same everywhere in that container. • Based on this principle, when piston is pressed a force was created inside the syringe, there is a stepper motor inside the pump, it controls the movement of syringe. Hence by the both actions syringe will move and inject the patient as set value. • Audible and visual alarms are available for patient safety. • KVO (Keep Vein open) mode is available here to prevent backflow and alarm will give indication to caretaker for empty syringe. • Automatic Syringe detector is enabled to pre check before injection. • Syringe pumps are more wisely used to inject medications rather than infusion pumps, since it is more fast and easy. • Bolus & anti-bolus functions available. • Less weight and portable, easy to mounded over stands. • Battery backup is available.
POWER SUPPLY |
DC 18V (1A) / 220 V AC |
BATTERY |
12V (800 mAh) NiMH Battery |
BATTERY BACKUP |
8hrs @ 5ml.hr Flow rate on 50ml Syringe |
POWER CONSUMPTION |
7 VA |
DISPLAY |
LCD & LED Display |
APPLICABLE SYRINGE |
2ml, 5ml, 10ml, 20ml, 30ml, 50/60ml & 100ml Syringes form any brand. |
AUTOMATIC SYRINGE SIZE DETECTOR |
Available |
FLOW RATE RANGE |
0.01 – 100 ml/Hr (2ml Syringe) |
INFUSED VOLUME |
0.1 – 9999 ml |
ELAPSED TIME |
Display of Elapsed time from 00:01 to 199:59 hrs |
DOSAGE TAPER Up/Down (Sequential Mode) |
Sequential program of 5 different Flow-rate at Different target time or volume available |
KVO |
0.1ml/Hr to 9.9ml/Hr in 0.1 ml increment |
BOLUS |
Purge Bolus & Auto Bolus |
BOLUS RATE FLOW |
0.1 – 100 ml/Hr (2ml Syringe) |
BOLUS VOLUME |
0.1ml to 10 ml in 0.1 ml increments |
OCCULUTION PRESSURE |
10 steps selection (OFF to 9 Levels) |
ANTI BOLUS FUNCTION |
Available |
EVENT LOG WITH RTC |
Available |
ALARMS |
AL 1 – Syringe holder disturbed during infusion |
AUDIO/VISUAL INDICATIONS AND ALARMS |
Target reached (time or volume), Occlusion, Syringe not engaged, Near to Empty, End of syringe, Battery mode, battery low, Internal mechanism fault, KVO Mode, Bolus Mode, SpO2 Mode, SpO2 Hi/Low alarms, PCA Mode, PCA probe disconnected, Patient end drug line |
MODES |
Flow Rate only, Flow Rate & Target volume, Flow Rate & Target Time, Target volume and target time, Drug library mode, Syringe pump with pulse oximeter Mode |
DRUG LIBRARY |
Available with 100 drug names. |
PCA (Optional) |
PCA dose can be preset from 0.1 to 10ml. |
ACCURACY |
Mechanical Accuracy ±1%, Including Syringe ± 3% |
SAFETY TESTING |
EN 60601-1. EN 60601-1-2, EN 60601-1-6, EN 60601-1-8, EN 60601-2-24 |
SPACE OCCUPIED |
2.4 ltrs |
WEIGHT &DIMENSIONS |
1.5 kg,170 x 107 x 135 ( L x B x H) |